Abstract: The application of detecting SF6 leaking by IR laser imaging system has an important signification. If the emission line of the grating tunable laser is right within the absorb range of SF6, the reflecting line can be received by the IR detector and the system will display the SF6 leaking situation. SF6 gas will absorb more IR spectrum around the center of 10.56μm, so high stability laser output and single output frequency are requested.
Key words: IR imaging, gas sensing, application of spectrum, SF6, CO2 laser
参考资料
1. Standoff Wide Area Detection of SF6 by Means of a Passive IR Imaging SpectrometerE.Robert Schildkraut and Raymond F. Connors Block Engineering, Marlborough, MA., 508/480-9643
2. ACCESS LASERCOMPANY http://www.access-laser.com/
3. Visualization of air flow using infrared thermography V. Narayanan, R.H. Page, J. Seyed-Yagoobi Experiments in Fluids 34 (2003) 275–284 DOI 10.1007/s00348-002-0557-x
4. NIST Chemistry Web Book, http://webbook.nist.gov/chemistry